Bitumen cannot be stored cold. A tank of about 40 m³ insulated over its whole surface, controlled heating that keeps the product at pumping temperature without ever overheating it, and an unloading unit with a heated gear pump that sends it to the asphalt plant. All of it inside a 40 ft ISO container, which travels by sea and sits on site with no civil works.
Designed for life after delivery. The tank rests on saddles welded to the chassis, the whole unit sits in a bund covering the full footprint, and the unloading and loading connections remain accessible with the doors closed. The manhole, the level gauge and the temperature probes are reached from a fixed ladder.
The model below reproduces a real unit: layout, colours and equipment dimensions taken from photographs. Rotate it, close the doors, make the walls transparent.
Internal dimensions in millimetres. Standard 40 ft container: 12,030 × 2,350 × 2,390 mm inside. The doors are on the left of the plan.
| Qty | Description |
|---|---|
| 1 | 40 ft ISO container, structure reinforced for the full-tank load, end doors |
| 1 | Steel bitumen storage tank, insulated, about 40 m³, dished ends, saddles welded to the chassis |
| 1 | 100 mm rock wool insulation under aluminium cladding, over the whole shell and both ends |
| 1 | Tank heating, thermostatically controlled, keeps the bitumen at pumping temperature |
| 1 | Bund under the full tank footprint, with drain point |
| 1 | Unloading unit: bitumen gear pump with heated casing, on a skid |
| 3 | Plug valves with heating jacket — suction, delivery, bottom drain |
| 2 | Unloading and loading connections, capped, accessible with the doors closed |
| 1 | Control cabinet: temperature control, pump start-stop, safety devices, remote alarm |
| 2 | Temperature probes, tank and delivery line |
| 1 | Level gauge with readout on the cabinet front |
| 1 | Manhole on top, access ladder and folding guardrail |
| 1 | Breather vent and degassing device |
| 4 | LED light bars, weatherproof sockets, cable tray |
Bitumen is stored hot: the whole point is to hold the temperature without ever overheating the product, which ages if it is cooked. The heating is therefore controlled and the tank is insulated over its whole surface, ends included — the ends are where the heat escapes when they are neglected.
Tank volume, heating power and heating method, and whether an unloading unit is needed, are all set from your asphalt production rate and the distance to your plant.
Tell us the volume, the bitumen grade and where the container needs to go: we will come back with a layout and a price.
Samuel Creiche · CREISCENDO · creiscendo@creiscendo.com · +33 6 76 18 78 74
© CREISCENDO 2026 · 11 rue Nationale, 37150 Chisseaux, France · creiscendo@creiscendo.com · +33 6 76 18 78 74 · en.creiscendo.com