Recent machines and trucks no longer run without urea, and urea tolerates neither sun nor high heat: above thirty degrees or so it degrades. This insulated, air-conditioned container protects it on a mine or a site in Africa, and dispenses it like a filling station. A 5,000 L double-wall tank in black polyethylene occupies the far end; a level gauge graduated from 0 to 5 m³ shows the level at a glance.
The container opens at both ends. On the technical side, the stainless-steel pipework, the filter and the transfer pump are mounted on galvanised rails along one wall, and the touch-screen control cabinet on the other, with the installation diagram, a convector heater and a fire extinguisher. On the dispensing side, a yellow-arm hose reel on a stand and its blue nozzle serve the machines without anyone entering the container. Built in two units.
Ready to travel: everything is secured. The tank is anchored to the floor, the pump bolted to its base, the pipework clamped to its rails, the cabinet and the air conditioner screwed to the walls. Nothing moves during transport and handling.
The model below is of an actual build, as close as possible to the photos: colours, dimensions and position of every item. Rotate it, open the doors at one end or the other, make the walls transparent.
Internal dimensions in millimetres, after insulation. 20-foot container, 6,058 × 2,438 × 2,591 mm outside, lined with white insulating panels: about 5,800 × 2,250 × 2,280 mm inside. Double-leaf doors at each end.
| Qty | Description |
|---|---|
| 1 | White 20-foot container, double-leaf doors at both ends, interior lined with insulating panels |
| 1 | Double-wall urea tank in black polyethylene, 5,000 L, Ø 1,940 × 1,920 mm, bolted manhole, grey PVC vents |
| 1 | Level gauge graduated from 0 to 5 m³, and level transmitter on the tank |
| 1 | Stainless-steel transfer pump on a galvanised base |
| 1 | Stainless-steel filter and three lines of stainless-steel pipework with motorised valves, on galvanised rails |
| 1 | Control cabinet 800 × 1,000 × 300 mm, light grey, touch screen, main switch, emergency stop, industrial sockets |
| 1 | Yellow-arm hose reel on an aluminium stand, hose and blue dispensing nozzle |
| 1 | Wall-mounted air conditioner, to keep the urea below 30 °C |
| 1 | Electric convector heater, against frost in the cold season or at altitude |
| 1 | Fire extinguisher |
| 2 | Wire-mesh cable trays in the upper corners, over the full length |
| 3 | Weatherproof LED light fittings |
The double wall serves as retention: if the inner tank leaks, the urea stays in the outer shell and does not reach the floor.
Nothing shown here is fixed. Tank volume, number of dispensing points, automation and metering: everything is reworked around your fleet and your consumption.
Tell us what you store and where the container needs to go: we will come back with a layout and a price.
Samuel Creiche · CREISCENDO · creiscendo@creiscendo.com · +33 6 76 18 78 74
© CREISCENDO 2026 · 11 rue Nationale, 37150 Chisseaux, France · creiscendo@creiscendo.com · +33 6 76 18 78 74 · en.creiscendo.com